Warnings, error and information messages¶
The exception messages of SilverStar Sewing Control System is divided into three groups, as shown in the following table:
Level |
Code |
Description |
|---|---|---|
Error |
Err |
Switch off the control and eliminate the problem |
Warning |
Wrn |
Eliminate the state that caused to the warning, the control will normally worked |
Information |
Inf |
Work can be continued, only exception message needs to be confirmed |
Exception quick reference¶
Error messages¶
Code |
Messages |
Remedial action |
|---|---|---|
ac power excess voltage |
||
bus excess voltage |
||
motor excess current |
||
overload/motor speed too low |
||
motor excess phase current |
||
motor blocked when start |
||
motor blocked |
||
motor uvw signal |
||
motor encoder error |
||
magnet/solenoid over-current |
||
motor encoder error |
||
panel connection error |
||
panel connection lost |
||
data checksum error |
||
stepper connection error |
||
data checksum error |
||
Controller: upgrade |
||
Controller: upgrade |
||
Controller: upgrade |
||
Controller: upgrade |
||
Controller: upgrade |
||
Controller: upgrade |
||
Controller: upgrade |
||
Controller: upgrade |
||
Controller: upgrade |
||
HMI: upgrade |
||
HMI: upgrade |
||
HMI: upgrade |
||
HMI: upgrade |
||
HMI: upgrade |
||
HMI: upgrade |
||
HMI: upgrade |
||
HMI: upgrade |
||
HMI: upgrade |
Warning messages¶
The code of the warning message is always less than 100.
Code |
Messages |
Remedial action |
|---|---|---|
pedal |
||
tilt switch |
||
shortkeys |
||
shortkeys |
||
bobbin counter/monitor |
||
upper thread breaking |
||
service counter |
||
eye protection |
||
slide monitoring |
Information messages¶
The code of the information message is always less than 100.
Code |
Messages |
Remedial action |
|---|---|---|
oil level |
Error message list¶
- exception ExcCode101¶
AC power supply voltage is too high
- solution()¶
Check the ac voltage; Replace the controller.
- exception ExcCode103¶
Bus voltage is too high
- solution()¶
Check the brake circuit, replace the brake resistor; Replace the controller.
- exception ExcCode106¶
The bus current is too high
- solution()¶
Check the motor encoder connection; Check if the right MACHINE ID is seted; Replace the controller;
- exception ExcCode107¶
Overload, the speed of main motor is too low
- solution()¶
The shaft is blocked; The material is too thick.
- exception ExcCode108¶
Overload, the current command of main motor exceeds the maximum value
- solution()¶
The shaft is blocked; The material is too thick.
- exception ExcCode109¶
The main motor starts failed
- solution()¶
Restart the machine from where the sewing material is thinner; The shaft is blocked; The material is too thick.
- exception ExcCode110¶
The synchronizer signal is not detected
- solution()¶
Check the synchronizaer signal; The shaft is blocked; The material is too thick.
- exception ExcCode111¶
Motor UVW signal is abnormal
- solution()¶
Check the UVW signal; Replace motor encoder
- exception ExcCode112¶
The motor synchronization signal cannot be detected for a long time after press the pedal.
- solution()¶
Check the synchronizaer signal; Replace motor encoder.
- exception ExcCode113¶
The solenoid current is too high
- solution()¶
Check the solenoid; Replace the controller or solenoid;
- exception ExcCode114¶
Abnormal value of motor angle
- solution()¶
Check the motor encoder connection; Check the hall sensor;
- exception ExcCode126¶
The paramter synchronization is failed
- solution()¶
Check the panel connection; Restart the control box
- exception ExcCode127¶
The panel is reconnected when some special mode
- solution()¶
Restart the controlbox
- exception ExcCode128¶
Parameters verified failed
- solution()¶
Restart the controlbox; Update software.
- exception ExcCode129¶
The step drive communication failed
- solution()¶
Restart the controlbox; Check the communication cable.
- exception ExcCode130¶
Parameters version verified failed
- solution()¶
Update the software of controlbox or panel.
- exception ExcCode192¶
Controller upgrade files data error: wrong page
- solution()¶
Copy the upgrade files and update again
- exception ExcCode193¶
Controller upgrade files data error: verification failed
- solution()¶
Copy the upgrade files and update again
- exception ExcCode194¶
Controller upgrade files data error: wrong size
- solution()¶
Copy the upgrade files and update again
- exception ExcCode195¶
Controller upgrade files data error: start address
- solution()¶
Copy the upgrade files and update again
- exception ExcCode196¶
Controller upgrade files data error: model not match
- solution()¶
Copy the upgrade files and update again
- exception ExcCode197¶
Controller upgrade files not exist
- solution()¶
Copy the upgrade files and update again
- exception ExcCode198¶
Communication timeout when upgrade the controller
- solution()¶
check wire connection and update again
- exception ExcCode182¶
Panel upgrade files data error: wrong page
- solution()¶
Copy the upgrade files and update again
- exception ExcCode183¶
Panel upgrade files data error: verification failed
- solution()¶
Copy the upgrade files and update again
- exception ExcCode184¶
Panel upgrade files data error: wrong size
- solution()¶
Copy the upgrade files and update again
- exception ExcCode185¶
Panel upgrade files data error: wrong start address
- solution()¶
Copy the upgrade files and update again
- exception ExcCode186¶
Panel upgrade files data error: model not match
- solution()¶
Copy the upgrade files and update again
- exception ExcCode187¶
Panel upgrade files not exist
- solution()¶
Copy the upgrade files and update again
Warning message list¶
- exception ExcCode1¶
Pedal warning
- solution()¶
The pedal must be released when switching on; The pedal type must be set correctly when using standing pedal; Replace the pedal.
- exception ExcCode2¶
Tilt switch warning
- solution()¶
The warning will be cleared when the machine is back to the normal position; Check the tipping sensor on the machine
- exception ExcCode5¶
Bobbin counter warning
- solution()¶
Replace the bobbin, press back key to clear warning
- exception ExcCode6¶
Upper thread breaking warning
- solution()¶
The upper thread is broken; Check the sensor of upper thread.
- exception ExcCode7¶
Service counter warning
- solution()¶
Make a service maintenance, press back key to clear warning