Warnings, error and information messages

The exception messages of SilverStar Sewing Control System is divided into three groups, as shown in the following table:

Level

Code

Description

Error

Err

Switch off the control and eliminate the problem

Warning

Wrn

Eliminate the state that caused to the warning, the control will normally worked

Information

Inf

Work can be continued, only exception message needs to be confirmed

Exception quick reference

Error messages

Code

Messages

Remedial action

ExcCode101

ac power excess voltage

ExcCode101.solution()

ExcCode103

bus excess voltage

ExcCode103.solution()

ExcCode106

motor excess current

ExcCode106.solution()

ExcCode107

overload/motor speed too low

ExcCode107.solution()

ExcCode108

motor excess phase current

ExcCode108.solution()

ExcCode109

motor blocked when start

ExcCode109.solution()

ExcCode110

motor blocked

ExcCode110.solution()

ExcCode111

motor uvw signal

ExcCode111.solution()

ExcCode112

motor encoder error

ExcCode112.solution()

ExcCode113

magnet/solenoid over-current

ExcCode113.solution()

ExcCode114

motor encoder error

ExcCode114.solution()

ExcCode126

panel connection error

ExcCode126.solution()

ExcCode127

panel connection lost

ExcCode127.solution()

ExcCode128

data checksum error

ExcCode128.solution()

ExcCode129

stepper connection error

ExcCode129.solution()

ExcCode130

data checksum error

ExcCode130.solution()

ExcCode191

Controller: upgrade

ExcCode191.solution()

ExcCode192

Controller: upgrade

ExcCode192.solution()

ExcCode193

Controller: upgrade

ExcCode193.solution()

ExcCode194

Controller: upgrade

ExcCode194.solution()

ExcCode195

Controller: upgrade

ExcCode195.solution()

ExcCode196

Controller: upgrade

ExcCode196.solution()

ExcCode197

Controller: upgrade

ExcCode197.solution()

ExcCode198

Controller: upgrade

ExcCode198.solution()

ExcCode199

Controller: upgrade

ExcCode199.solution()

ExcCode181

HMI: upgrade

ExcCode181.solution()

ExcCode182

HMI: upgrade

ExcCode182.solution()

ExcCode183

HMI: upgrade

ExcCode183.solution()

ExcCode184

HMI: upgrade

ExcCode184.solution()

ExcCode185

HMI: upgrade

ExcCode185.solution()

ExcCode186

HMI: upgrade

ExcCode186.solution()

ExcCode187

HMI: upgrade

ExcCode187.solution()

ExcCode188

HMI: upgrade

ExcCode188.solution()

ExcCode189

HMI: upgrade

ExcCode189.solution()

Warning messages

The code of the warning message is always less than 100.

Code

Messages

Remedial action

ExcCode1

pedal

ExcCode1.solution()

ExcCode2

tilt switch

ExcCode2.solution()

ExcCode3

shortkeys

ExcCode3.solution()

ExcCode4

shortkeys

ExcCode4.solution()

ExcCode5

bobbin counter/monitor

ExcCode5.solution()

ExcCode6

upper thread breaking

ExcCode6.solution()

ExcCode7

service counter

ExcCode7.solution()

ExcCode8

eye protection

ExcCode8.solution()

ExcCode9

slide monitoring

ExcCode9.solution()

Information messages

The code of the information message is always less than 100.

Code

Messages

Remedial action

ExcCode50

oil level

ExcCode50.solution()

Error message list

exception ExcCode101

AC power supply voltage is too high

solution()

Check the ac voltage; Replace the controller.

exception ExcCode103

Bus voltage is too high

solution()

Check the brake circuit, replace the brake resistor; Replace the controller.

exception ExcCode106

The bus current is too high

solution()

Check the motor encoder connection; Check if the right MACHINE ID is seted; Replace the controller;

exception ExcCode107

Overload, the speed of main motor is too low

solution()

The shaft is blocked; The material is too thick.

exception ExcCode108

Overload, the current command of main motor exceeds the maximum value

solution()

The shaft is blocked; The material is too thick.

exception ExcCode109

The main motor starts failed

solution()

Restart the machine from where the sewing material is thinner; The shaft is blocked; The material is too thick.

exception ExcCode110

The synchronizer signal is not detected

solution()

Check the synchronizaer signal; The shaft is blocked; The material is too thick.

exception ExcCode111

Motor UVW signal is abnormal

solution()

Check the UVW signal; Replace motor encoder

exception ExcCode112

The motor synchronization signal cannot be detected for a long time after press the pedal.

solution()

Check the synchronizaer signal; Replace motor encoder.

exception ExcCode113

The solenoid current is too high

solution()

Check the solenoid; Replace the controller or solenoid;

exception ExcCode114

Abnormal value of motor angle

solution()

Check the motor encoder connection; Check the hall sensor;

exception ExcCode126

The paramter synchronization is failed

solution()

Check the panel connection; Restart the control box

exception ExcCode127

The panel is reconnected when some special mode

solution()

Restart the controlbox

exception ExcCode128

Parameters verified failed

solution()

Restart the controlbox; Update software.

exception ExcCode129

The step drive communication failed

solution()

Restart the controlbox; Check the communication cable.

exception ExcCode130

Parameters version verified failed

solution()

Update the software of controlbox or panel.

exception ExcCode191

Controller upgrade files data error: wrong file

solution()

Update software

exception ExcCode192

Controller upgrade files data error: wrong page

solution()

Copy the upgrade files and update again

exception ExcCode193

Controller upgrade files data error: verification failed

solution()

Copy the upgrade files and update again

exception ExcCode194

Controller upgrade files data error: wrong size

solution()

Copy the upgrade files and update again

exception ExcCode195

Controller upgrade files data error: start address

solution()

Copy the upgrade files and update again

exception ExcCode196

Controller upgrade files data error: model not match

solution()

Copy the upgrade files and update again

exception ExcCode197

Controller upgrade files not exist

solution()

Copy the upgrade files and update again

exception ExcCode198

Communication timeout when upgrade the controller

solution()

check wire connection and update again

exception ExcCode199

No USB drive detected

solution()

Reinsert the USB disk and update again

exception ExcCode181

Wrong panel software

solution()

Update software

exception ExcCode182

Panel upgrade files data error: wrong page

solution()

Copy the upgrade files and update again

exception ExcCode183

Panel upgrade files data error: verification failed

solution()

Copy the upgrade files and update again

exception ExcCode184

Panel upgrade files data error: wrong size

solution()

Copy the upgrade files and update again

exception ExcCode185

Panel upgrade files data error: wrong start address

solution()

Copy the upgrade files and update again

exception ExcCode186

Panel upgrade files data error: model not match

solution()

Copy the upgrade files and update again

exception ExcCode187

Panel upgrade files not exist

solution()

Copy the upgrade files and update again

exception ExcCode188

Communication timeout when upgrade the panel

solution()

check wire connection and update again

exception ExcCode189

No USB drive detected

solution()

Copy the upgrade files and update again

Warning message list

exception ExcCode1

Pedal warning

solution()

The pedal must be released when switching on; The pedal type must be set correctly when using standing pedal; Replace the pedal.

exception ExcCode2

Tilt switch warning

solution()

The warning will be cleared when the machine is back to the normal position; Check the tipping sensor on the machine

exception ExcCode3

Shortkey warning

solution()

The short key must be released when switching on

exception ExcCode4

Shortkey warning

solution()

The short key must be released when switching on

exception ExcCode5

Bobbin counter warning

solution()

Replace the bobbin, press back key to clear warning

exception ExcCode6

Upper thread breaking warning

solution()

The upper thread is broken; Check the sensor of upper thread.

exception ExcCode7

Service counter warning

solution()

Make a service maintenance, press back key to clear warning

exception ExcCode8

Eye protection monitoring

solution()

Put eye protection cover plate back in place; Check the sensor of eye protection.

exception ExcCode9

Slide monitoring

solution()

Close the hook cover plate; Check the sensor of slide monitoring;

Information message list

exception ExcCode50

Oil level is below the minimum level marking

solution()

Maintenance necessary, see the service instructions for the machine to lubricating the machine

Changed in version 90A0-v1.08.05: Previously, the code of this exception was 10 and belonged to warning group.