Safety Sensor

Tilt safety/Finger protection/Hook cover protection.

Tilt safaty switch

Quick reference

This table summarizes which parameter should be used for tilt safaty switch:

Parameter

Authority

See also

Tilt Switch Debounce

Technician

T09

Warning: Tilt safety switch

Technician

O31

Sensor Polarity(Tilt Safety)

Technician

O32

Eye protection

Quick reference

This table summarizes which parameter should be used for eye protection:

Parameter

Authority

See also

Warning: Eye protection

Technician

O28

Slide monitoring

Quick reference

This table summarizes which parameter should be used for slide monitoring:

Parameter

Authority

See also

Warning: Slide monitoring

Technician

O29

Oil Level

Quick reference

This table summarizes which parameter should be used for oil level:

Parameter

Authority

See also

Information: Oil Level

Technician

O34

Oil Level Sample

Technician

O68

Upper Thread Breaking

Quick reference

This table summarizes which parameter should be used for upper thread breaking:

Parameter

Authority

See also

Warning: Upper Thread Break

Technician

A53

Upper Thread Monitor Debounce

Technician

T13

Sensor Polarity(Upper Thread Breaking)

Technician

O92

Parameter List

T09
-Max

1000

-Min

1

-Unit

ms

-Description

Delay for the signal evaluation of the tilt switch input.

O31
-Max

1

-Min

0

-Unit

-Description
Whether to throw a warning when the machine is tilted:
0 = Off;
1 = On.
O32
-Max

1

-Min

0

-Unit

-Description
Sensor polarity used for detect whether the machine has tilted:
0 = Normal close;
1 = Normal open.
O28
-Max

1

-Min

0

-Unit

-Description
Optional features,whether to throw a warning when the eye protection isn’t in the right place:
0 = Off;
1 = On.
O29
-Max

1

-Min

0

-Unit

-Description
Optional features,whether to throw a warning when the hook cover plate is removed:
0 = Off;
1 = On.
O34
-Max

1

-Min

0

-Unit

-Description
Optional features, whether to throw a information when the lubricating oil level is too low:
0 = Off;
1 = On.
O68
-Max

4095

-Min

0

-Unit

-Description

If lubricating oil level sensor signal is analog, and the actual sampling value is lower than this parameter value, a low oil level exception will be thrown.

A53
-Max

1

-Min

0

-Unit

-Description
Optional features, whether to throw a warning when the upper thread breaking:
0 = Off;
1 = On.
T13
-Max

1000

-Min

1

-Unit

ms

-Description

Delay for the signal evaluation of the upper thread monitor.

O92
-Max

1

-Min

0

-Unit

-Description
Sensor polarity used for upper thread breaking:
0 = Normal open;
1 = Normal closed.