Stroke adjustment¶
Depending on the equipment, the machine has can be used to sew two different storke heights, and it can be activated with a press of button.
Speed Limitation via adjusting wheel¶
If additional components are installed within the stroke adjustment wheel, the system
will automatically limit speed when adjusting the wheel. Parameter O85 is used
to set the component type. If set to 0, no speed limit applies when adjusting stroke
using the wheel.
There are two types of components used for speed limiting:
- Switch
Set
O85to 1.Gear speed limiter, if two switches are installed, it will have four gears.
- Potentiometer
Set
O85to 2.The sew speed is continuously adjustable, The system maintains the full programmed speed until a certain stroke height is reached As the stroke height continues to increase, the maximum sewing speed will decrease linearly.
Important
Ensure that the larger the stroke level, the smaller the potentiometer sampling value.
Set maximum speed using parameter
S10Set minimum speed using parameter
S14Set sample value of upper break point using parameter
O21, stroke level up to which full speed is to be maintainedSet sample value of upper break point using parameter
O22, stroke level from which minimum speed is to be effectiveCorrespondence between sampling value parameters and speed parameters¶
Speed Limitation during quick stroke adjustment¶
If parameter A35 set to 1, when 2nd sewing foot stroke is activated, the speed
is reduced down to the desired value of 2nd sewing foot stroke which set by
S15.
Quick Stroke Auto-Reset Stitches¶
if A32 is not 0, when switching to 2nd sewing foot stroke, after sewing N
stitches set by A32 , the second sewing foot stroke is automatically
deactivated.
Quick reference¶
This table summarizes which parameter should be used for stroke:
Parameter |
Authority |
See also |
|---|---|---|
Stroke |
Operator |
|
Stroke Limit Level 1 |
Technician |
|
Linear Limit Start |
Technician |
|
Stroke Limit Level 2 |
Technician |
|
Stroke Limit Level 3 |
Technician |
|
Stroke Limit Level 1 |
Technician |
|
Linear Limit End |
Technician |
|
Max. Stroke Speed Limit |
Technician |
|
Quick Stroke Auto-Reset Stitches |
Technician |
|
Quick Stroke Adjustment Status |
Developer |
|
Quick stroke adjustment auto speed limit |
Operator |
|
Sample value of upper speed break point |
Technician |
|
Sample value of lower speed break point |
Technician |
|
Full power duration |
Developer |
|
Duty cycle after full power |
Developer |
|
The Stroke Height Sensor Type |
Developer |
Parameter List¶
- A45¶
- -Max
1
- -Min
0
- -Unit
–
- -Description
- Sewing foot stroke:0 = Off;1 = On.
- S09¶
- -Max
4500
- -Min
50
- -Unit
spm
- -Description
Switch Type: Speed limit for stroke height level 1.
- S10¶
- -Max
4500
- -Min
50
- -Unit
spm
- -Description
Potentiometer Type: Limit speed at the start of linear reduction.
- S11¶
- -Max
4500
- -Min
50
- -Unit
spm
- -Description
Switch Type: Speed limit for stroke height level 2.
- S12¶
- -Max
4500
- -Min
50
- -Unit
spm
- -Description
Switch Type: Speed limit for stroke height level 3.
- S13¶
- -Max
4500
- -Min
50
- -Unit
spm
- -Description
Switch Type: Speed limit for stroke height level 4.
- S14¶
- -Max
4500
- -Min
50
- -Unit
spm
- -Description
Potentiometer Type: Limit speed at the end of linear reduction.
- S15¶
- -Max
4500
- -Min
50
- -Unit
spm
- -Description
Safety speed limit at the maximum stroke height.
- A24¶
- -Max
1
- -Min
0
- -Unit
–
- -Description
Activation status of the Quick Stroke Adjustment, read only.
- A32¶
- -Max
99
- -Min
0
- -Unit
stitches
- -Description
- Number of stitches for automatic switch off the 2nd stroke:0 = Manual;Not 0 = Number of stitches after which quick stroke adjustment is automatically deactivated.
- A35¶
- -Max
1
- -Min
0
- -Unit
–
- -Description
- Limits maximum speed automatically during quick stroke adjustment:0 = Off;1 = On, if the second stroke is activated, speed reduced down to Parameter
S15.
- O21¶
- -Max
4095
- -Min
0
- -Unit
–
- -Description
Sample value of upper break point, stroke level up to which full speed is to be maintained.
- O22¶
- -Max
4095
- -Min
0
- -Unit
–
- -Description
Sample value of upper break point, stroke level from which minimum speed is to be effective.
- O76¶
- -Max
999
- -Min
1
- -Unit
ms
- -Description
Stroke height: Activation duration in time period t1 (100% duty cycle).
- O77¶
- -Max
100
- -Min
1
- -Unit
%
- -Description
Stroke height: Duty cycle [%] in time period t2 .
- O85¶
- -Max
2
- -Min
0
- -Unit
–
- -Description
- Type of stroke adjustment sensor:0 = No;1 = Switch;2 = Potentiometer.