Control, other

Quick reference

This table summarizes which parameter should be used for control and other:

Parameter

Authority

See also

Data Sending Interval

Technician

T14

IoT

Technician

A49

Lock Panel

Technician

A52

Debug

Developer

A58

Reset statisc data

Technician

A59

Password Required

Technician

O15

Clear error log

Technician

O17

Password

Technician

O27

Reset parameter

Technician

O51

Reset the MACHINE ZERO

Technician

O52

Factory reset

Technician

O66

Bus Voltage Error Reporting

Technician

O70

AC Voltage Error Reporting

Technician

O71

Max. Bus Voltage

Technician

I44

Max. AC Voltage

Technician

I45

Parameter List

T14
-Max

9999

-Min

1

-Unit

ms

-Description

Interval time for sending IoT data.

A49
-Max

1

-Min

0

-Unit

-Description
IoT network:
0 = Off;
1 = On.
A52
-Max

1

-Min

0

-Unit

-Description
Whether the panel can be operated when foot lifting:
0 = Not allowed;
1 = Allowed.
A58
-Max

1

-Min

0

-Unit

-Description
Debug serial port output function:
0 = Off;
1 = On.
A59
-Max

1

-Min

0

-Unit

-Description

Set to 1, statisc data will be restored to default values after power cycle.

O15
-Max

1

-Min

0

-Unit

-Description
Whether a password is required for parameter adjustment:
0 = Off;
1 = On.
O17
-Max

1

-Min

0

-Unit

-Description

Set to 1,error log clead after power cycle.

O27
-Max

1

-Min

0

-Unit

-Description

Password required to adjust parameters.

O51
-Max

1

-Min

0

-Unit

-Description

Set to 1, parameters will be restored to default values after power cycle.

O52
-Max

1

-Min

0

-Unit

-Description

Set to 1,the MACHINE ZERO will be reset after power cycle.

O66
-Max

1

-Min

0

-Unit

-Description

Set to 1,reset all parameters to default value,clear the error log and stastics information,reset MACHINE ZERO after power cycle.

O70
-Max

1

-Min

0

-Unit

-Description
Whether to throw a error if bus voltage is too high:
0 = Off;
1 = On.
O71
-Max

1

-Min

0

-Unit

-Description
Whether to throw a error if AC 220 voltage is too high:
0 = Off;
1 = On.
I44
-Max

460

-Min

400

-Unit

V

-Description

Maximum bus voltage.

I45
-Max

300

-Min

260

-Unit

V

-Description

Maximum AC voltage.