Thread trimmer

Thread trimming procedure

Thread trimmer singnal is switched on when the angle value D03 has been reached, the switched off when the angle value D04 . If the position is not reached because of a mechanical error, the thread trimmer signal is switched off after 500ms for protect the magnet from damage.

Thread trimming in the lockstitch modes is performed at trimming speed.

Activation of Short Trimmer

With sewing machines equipped with a short trimmer system, the required functional sequence can be activated using parameter A42. The thread trimming function must be On.

Quick reference

This table summarizes which parameter should be used for thread trimmer:

Parameter

Authority

See also

Thread trimmer

Operator

A06

Thread trimming speed

Technician

S07

Short Trimmer

Technician

A42

Short Trimmer Stitches

Technician

A67

Switch-on angle for Thread trimmer

Technician

D03

Switch-off angle for Thread trimmer

Technician

D04

Switch-on angle for Movable Knife of Short Trimmer

Technician

D17

Switch-off angle for Movable Knife of Short Trimmer

Technician

D18

Switch-on angle for Reverse of Short Trimmer

Technician

D19

Switch-off angle for Reverse of Short Trimmer

Technician

D20

Switch-on angle for Zero stitch length of Short Trimmer

Technician

D21

Switch-off angle for Zero stitch length of Short Trimmer

Technician

D22

Pedal Reset After Trim

Technician

O38

Zero stitch length of short trimmer: Full power duration

Developer

O95

Zero stitch length of short trimmer: Duty cycle after full

Developer

O96

power

Parameter List

A06
-Max

1

-Min

0

-Unit

-Description
Thread trimmer:
0 = Off;
1 = On.
S07
-Max

1000

-Min

50

-Unit

spm

-Description

TMachine speed during the thread trimming.

A42
-Max

1

-Min

0

-Unit

-Description
Short Trimmer, feature for specific models:
0 = Off;
1 = On.
A67
-Max

10

-Min

0

-Unit

stitches

-Description

When short thread trimmer is On, number of short length stitches before trim.

D03
-Max

359

-Min

0

-Unit

-Description

Switch-on angle for thread trimmer.

D04
-Max

359

-Min

0

-Unit

-Description

Switch-off angle for thread trimmer.

D17
-Max

359

-Min

0

-Unit

-Description

Switch-on angle for movable knife of short trimmer.

D18
-Max

359

-Min

0

-Unit

-Description

Switch-off angle for movable knife of short trimmer.

D19
-Max

359

-Min

0

-Unit

-Description

Switch-on angle for the reverse of short trimmer.

D20
-Max

359

-Min

0

-Unit

-Description

Switch-on angle for the reverse of short trimmer.

D21
-Max

359

-Min

0

-Unit

-Description

Switch-on angle for the zero stitch length of short trimmer.

D22
-Max

359

-Min

0

-Unit

-Description

Switch-off angle for the zero stitch length of short trimmer.

O38
-Max

1

-Min

0

-Unit

-Description
Whether the pedal need to return Position 0 before restart a new seam after trim:
0 = Off;
1 = On.
O95
-Max

999

-Min

1

-Unit

ms

-Description

Zero stitch length of short trimmer: Activation duration in time period t1 (100% duty cycle).

O96
-Max

100

-Min

1

-Unit

%

-Description

Zero stitch length of short trimmer: Duty cycle [%] in time period t2 .