Thread trimmer¶
- Thread trimming procedure
Thread trimmer singnal is switched on when the angle value
D03has been reached, the switched off when the angle valueD04. If the position is not reached because of a mechanical error, the thread trimmer signal is switched off after 500ms for protect the magnet from damage.Thread trimming in the lockstitch modes is performed at trimming speed.
Activation of Short Trimmer¶
With sewing machines equipped with a short trimmer system, the required functional
sequence can be activated using parameter A42. The thread trimming function
must be On.
Quick reference¶
This table summarizes which parameter should be used for thread trimmer:
Parameter |
Authority |
See also |
|---|---|---|
Thread trimmer |
Operator |
|
Thread trimming speed |
Technician |
|
Short Trimmer |
Technician |
|
Short Trimmer Stitches |
Technician |
|
Switch-on angle for Thread trimmer |
Technician |
|
Switch-off angle for Thread trimmer |
Technician |
|
Switch-on angle for Movable Knife of Short Trimmer |
Technician |
|
Switch-off angle for Movable Knife of Short Trimmer |
Technician |
|
Switch-on angle for Reverse of Short Trimmer |
Technician |
|
Switch-off angle for Reverse of Short Trimmer |
Technician |
|
Switch-on angle for Zero stitch length of Short Trimmer |
Technician |
|
Switch-off angle for Zero stitch length of Short Trimmer |
Technician |
|
Pedal Reset After Trim |
Technician |
|
Zero stitch length of short trimmer: Full power duration |
Developer |
|
Zero stitch length of short trimmer: Duty cycle after full |
Developer |
|
power |
Parameter List¶
- A06¶
- -Max
1
- -Min
0
- -Unit
–
- -Description
- Thread trimmer:0 = Off;1 = On.
- S07¶
- -Max
1000
- -Min
50
- -Unit
spm
- -Description
TMachine speed during the thread trimming.
- A42¶
- -Max
1
- -Min
0
- -Unit
–
- -Description
- Short Trimmer, feature for specific models:0 = Off;1 = On.
- A67¶
- -Max
10
- -Min
0
- -Unit
stitches
- -Description
When short thread trimmer is On, number of short length stitches before trim.
- D03¶
- -Max
359
- -Min
0
- -Unit
1°
- -Description
Switch-on angle for thread trimmer.
- D04¶
- -Max
359
- -Min
0
- -Unit
1°
- -Description
Switch-off angle for thread trimmer.
- D17¶
- -Max
359
- -Min
0
- -Unit
1°
- -Description
Switch-on angle for movable knife of short trimmer.
- D18¶
- -Max
359
- -Min
0
- -Unit
1°
- -Description
Switch-off angle for movable knife of short trimmer.
- D19¶
- -Max
359
- -Min
0
- -Unit
1°
- -Description
Switch-on angle for the reverse of short trimmer.
- D20¶
- -Max
359
- -Min
0
- -Unit
1°
- -Description
Switch-on angle for the reverse of short trimmer.
- D21¶
- -Max
359
- -Min
0
- -Unit
1°
- -Description
Switch-on angle for the zero stitch length of short trimmer.
- D22¶
- -Max
359
- -Min
0
- -Unit
1°
- -Description
Switch-off angle for the zero stitch length of short trimmer.
- O38¶
- -Max
1
- -Min
0
- -Unit
–
- -Description
- Whether the pedal need to return Position 0 before restart a new seam after trim:0 = Off;1 = On.
- O95¶
- -Max
999
- -Min
1
- -Unit
ms
- -Description
Zero stitch length of short trimmer: Activation duration in time period t1 (100% duty cycle).
- O96¶
- -Max
100
- -Min
1
- -Unit
%
- -Description
Zero stitch length of short trimmer: Duty cycle [%] in time period t2 .