Second stitch length

Connect a button and configure its corresponding input port for stitch length switching, allowing you to quickly switch between two stitch lengths.

Speed Limitation when long stitch length activated

If parameter O33 set to 1, the speed is reduced down to parameter S17 when long stitch length activated.

Quick reference

This table summarizes which parameter should be used for second stitch length:

Parameter

Authority

See also

Second Stitch Length

Operator

A46

Long Stitch Speed Limit

Operator

S17

Stitch Length Switching Status

Technician

A25

Stitch length during backtack

Technician

A50

Speed limit during long stitch length

Technician

O33

Full power duration

Developer

O78

Duty cycle after full power

Developer

O79

Parameter List

A46
-Max

1

-Min

0

-Unit

-Description
Second Stitch Length:
0 = Off;
1 = On.
S17
-Max

4500

-Min

50

-Unit

spm

-Description

Speed limit when using long stitch length.

A25
-Max

1

-Min

0

-Unit

-Description

Whether the stitch length switching is activated, read only.

A50
-Max

1

-Min

0

-Unit

-Description
When sewing start or end backtack, automatically switch to small stitch length:
0 = Off;
1 = On.
O33
-Max

1

-Min

0

-Unit

-Description
Speed limit during long stitch length:
0 = Off;
1 = On.
O78
-Max

999

-Min

1

-Unit

ms

-Description

Second stitch length: Activation duration in time period t1 (100% duty cycle).

O79
-Max

100

-Min

1

-Unit

%

-Description

Second stitch length: duty cycle after full power in time period t2.