Service counter

Using service counter allows users to remind regular mechanical maintenance.

Quick start

Following steps:

  1. Set an appropriate value for A62, every time N stitches are sewn which set by this parameter, the counter value A63 increases by 1.

  2. Set an appropriate value for A61, this is a very variable value, which depends on how often you want to maintain.

  3. Set A60 to 1, enable the counter.

  4. Refer to the beginning of this chapter Service Remaining Amount, as the sewing, the remaining amount is counted down, when it reaches 0, the machine will stop, and the controller will throw a warning. If you want to continue, you need to perform a reset operation.

How it works?

(1)\[N_{\text{Remaining amount}} = A61_{\text{reset value of the service counter}} - A63_{\text{service counter value}}\]

Quick reference

This table summarizes which parameter should be used for service counter:

Parameter

Authority

See also

Service Stitch Counter

Operator

A60

Service Counter Reset Value

Technician

A61

Service Counter Factor

Technician

A62

Service Counter Value

Technician

A63

Parameter List

A60
-Max

1

-Min

0

-Unit

-Description
Active service stitch counter:
0 = Off;
1 = On.
A61
-Max

9999

-Min

1

-Unit

-Description

Reset value of service stitch counter.

A62
-Max

200

-Min

1

-Unit

stitches

-Description

Every sew over this number of stitches,increment the counter by 1.

A63
-Max

9999

-Min

0

-Unit

-Description

The current value of service stitch counter.