Thread wiper

Thread wiper has two different action modes:

  • Mode 1

    Set A08 to 1 to enable this function.

    When thread trimmer is completed and the time set by T03 is delayed, the wiper will switch on, it will switch off after the time set by T04.

  • Mode 2

    Set A08 to 2 to enable this function.

    When thread trimmer is completed, while lifting the foot for the first time, the wiper will switch on, it will switch off after the time set by T04.

Quick reference

This table summarizes which parameter should be used for wiper:

Parameter

Authority

See also

Thread wiper

Operator

A08

Wiper Delay

Technician

T03

Wiper Time

Technician

T04

Parameter List

A08
-Max

1

-Min

0

-Unit

-Description
Wiper thread:
0 = Off;
1 = Mode 1;
2 = Mode 2.
T03
-Max

200

-Min

1

-Unit

ms

-Description

Delay time between thread trimming and wiper activation.

T04
-Max

200

-Min

1

-Unit

ms

-Description

Switch-on duration for the wiper.